<code id="ng627"></code>

  • <code id="ng627"></code>
  • <tr id="ng627"></tr>

    <tr id="ng627"></tr>

      1. <output id="ng627"><track id="ng627"></track></output>
        product thumbnail
               

        儲能系統
        (Energy Storage System)

         

        ESS is designed to suit your installation environment and requirements and container-based installation(4MW PCS in a 40ft container) offers a number of options for optimal configuration.

        • Products
        • Applications
        • Benefits
        • 下載
        • 客戶支持

        Products

        Power Management System (PMS)

        Integrated monitoring and control system of ESS provide optimal solutions for commercial and industrial end-users.
        The Operation Center allows convenient and effective operation of ESS with simple clicks of a mouse.

        • · Operation Mode
          • - Schedule-based load leveling
          • - Demand-based peak shaving
          • - Independent operating substituting diesel generator
        • · Main Fuctions
          • - Monitoring and control of PCS, battery and other equipment
          • - Analysis of operational effectiveness such as cost saving
        • · PMS Operation Screen

        PA1602_ESS_01.pNG

        • The energy flow on the grid system is displayed in map-type diagrams to assist intuitive monitoring of ESS operation status.

        PA1602_ESS_02.png

        • ESS operation is updated on a real-time basis and is presented in graphs with immediate estimation of costs saved.

        Power Conditioning System (PCS)

        MW-level EnGather runs on bi-directional power control algorithms with excellent dynamic characteristics and performs stable charging/discharging control between the grid system and high energy-density batteries.
        PCS is configured with stack modules for easy maintenance and is highly reliable in various applications(frequency regulation, emergency generator, load leveling, wind power, etc.)

        • · MW-level power control
        • · Quick response
        • · High efficiency (98% at rated power)
        • · Bi-directional power conversion
        • · Active/ reactive power control
        • · Power factor control
        • · Easy maintenance

        PA1602_ESS_03.jpg

        ModelLSEP-2000G1a(KOR)LSEP-1000G1a(KOR)LSEP-1000G1b(KOR)LSEP-1000G1c(US)
        ACRated Output2MW1MW1MW1MW
        Rated Voltage3 ? 440VAC3 ? 380VAC3 ? 440VAC3 ? 480VAC
        Current Output2,624A1,519A1,312A1,202A
        Frequency60Hz60Hz60Hz60Hz
        Current HarmonicsTHD : total 5%, individual<3%
        EfficiencyMax. 98%, >96% (at rated power, discharging efficiency)
        DCBattery Voltage750 to 1,050Vdc576 to 787Vdc750 to 1,050Vdc750 to 1,000Vdc
        Battery Current2,666A1,736A1,333A1,400A
        StandardSGSF-04-2012-07IEEE1547a, UL1741, UL1998
        CommunicationsModbus TCP, (DNP3.0 Option)
        Ambient
          Environment
        Cooling MethodForced-air cooling
        Operating Temperature-10°C ~ 40°C-5°C ~ 40°C
        HousingIPIP20/ IP21
        Dimensions(mm)5,650W x 1,130D x 2,020H2,910W x 1,130D x 2,020H2,510Wx1,126Dx2,020H

        HMI (Human Machine Interface) Display

        It is mounted on the PCS panel and the operator can monitor and control PCS operation through HMI.

        • · Feature
          • - Touch-panel 8.4” color LCD screen
          • - Real-time monitoring and diagnosis
          • - USB 2.0

        PA1602_ESS_04.bmp

        • Grid connection mode

        PA1602_ESS_05.bmp

        • Emergency generation mode

        Applications

        PA1602_ESS_06.png

        Benefits

        Renewable Energy

        PA1602_ESS_07.jpg

        · Smoothing Control
        Renewable energy sources are unpredictable and the availability of renewable energy is not constant, all of which may undermine quality of the grid system.
        When connected with ESS, quality electricity can be supplied to the grid system in a stable manner

        Frequency Regulation

        PA1602_ESS_08.jpg

        · Frequency Regulation
        A gap between power generation and demand on the grid causes the grid frequency to move away from its nominal value, and this can be regulated using ESS to improve quality of electricity.
        Deploying ESS can also maximize utilization of coal-fired power plants to reduce power cost.

        Commercial/Industrial/Housing

        PA1602_ESS_09.jpgPA1602_ESS_10.jpg

        · Load Leveling
        Time of use electricity pricing has three different pricing for light load, heavy load and maximum load. Electricity is charged during hours of light load and discharged during maximum load to reduce energy charge on your bill.
        · Back-up Power
        In case of blackout, ESS supplies electricity enabling swift response to emergencies.
        · Peak Shaving
        When electricity usage goes beyond what is contracted, electricity will be provided by ESS to prevent demand charge on your bill from going up.

        Microgrid

        PA1602_ESS_11.jpg

        · Grid connection/stand-alone
        A microgrid is a discrete energy system consisting of diesel power generation, renewable energy, ESS, etc. and loads capable of operating in parallel with, or independently from, the main power grid.
        ESS helps stabilize the grid system through power smoothing control as well as voltage and frequency regulation.

        BSS

        PA1602_ESS_12.jpg

        · Battery Swapping Station (BSS)
        BSS is an optimal charging station for automatic battery swapping electric buses. When battery is running out of energy, a robot removes the battery pack from the bus and places on the top of the charging station for charging.
        Bus stops are equipped with charging stations and battery is changed while the bus is stopped at bus stops.

        Products

        Power Management System (PMS)

        Integrated monitoring and control system of ESS provide optimal solutions for commercial and industrial end-users.
        The Operation Center allows convenient and effective operation of ESS with simple clicks of a mouse.

        • · Operation Mode
          • - Schedule-based load leveling
          • - Demand-based peak shaving
          • - Independent operating substituting diesel generator
        • · Main Fuctions
          • - Monitoring and control of PCS, battery and other equipment
          • - Analysis of operational effectiveness such as cost saving
        • · PMS Operation Screen

        PA1602_ESS_01.pNG

        • The energy flow on the grid system is displayed in map-type diagrams to assist intuitive monitoring of ESS operation status.

        PA1602_ESS_02.png

        • ESS operation is updated on a real-time basis and is presented in graphs with immediate estimation of costs saved.

        Power Conditioning System (PCS)

        MW-level EnGather runs on bi-directional power control algorithms with excellent dynamic characteristics and performs stable charging/discharging control between the grid system and high energy-density batteries.
        PCS is configured with stack modules for easy maintenance and is highly reliable in various applications(frequency regulation, emergency generator, load leveling, wind power, etc.)

        • · MW-level power control
        • · Quick response
        • · High efficiency (98% at rated power)
        • · Bi-directional power conversion
        • · Active/ reactive power control
        • · Power factor control
        • · Easy maintenance

        PA1602_ESS_03.jpg

        ModelLSEP-2000G1a(KOR)LSEP-1000G1a(KOR)LSEP-1000G1b(KOR)LSEP-1000G1c(US)
        ACRated Output2MW1MW1MW1MW
        Rated Voltage3 ? 440VAC3 ? 380VAC3 ? 440VAC3 ? 480VAC
        Current Output2,624A1,519A1,312A1,202A
        Frequency60Hz60Hz60Hz60Hz
        Current HarmonicsTHD : total 5%, individual<3%
        EfficiencyMax. 98%, >96% (at rated power, discharging efficiency)
        DCBattery Voltage750 to 1,050Vdc576 to 787Vdc750 to 1,050Vdc750 to 1,000Vdc
        Battery Current2,666A1,736A1,333A1,400A
        StandardSGSF-04-2012-07IEEE1547a, UL1741, UL1998
        CommunicationsModbus TCP, (DNP3.0 Option)
        Ambient
          Environment
        Cooling MethodForced-air cooling
        Operating Temperature-10°C ~ 40°C-5°C ~ 40°C
        HousingIPIP20/ IP21
        Dimensions(mm)5,650W x 1,130D x 2,020H2,910W x 1,130D x 2,020H2,510Wx1,126Dx2,020H

        HMI (Human Machine Interface) Display

        It is mounted on the PCS panel and the operator can monitor and control PCS operation through HMI.

        • · Feature
          • - Touch-panel 8.4” color LCD screen
          • - Real-time monitoring and diagnosis
          • - USB 2.0

        PA1602_ESS_04.bmp

        • Grid connection mode

        PA1602_ESS_05.bmp

        • Emergency generation mode

        Applications

        PA1602_ESS_06.png

        Benefits

        Renewable Energy

        PA1602_ESS_07.jpg

        · Smoothing Control
        Renewable energy sources are unpredictable and the availability of renewable energy is not constant, all of which may undermine quality of the grid system.
        When connected with ESS, quality electricity can be supplied to the grid system in a stable manner

        Frequency Regulation

        PA1602_ESS_08.jpg

        · Frequency Regulation
        A gap between power generation and demand on the grid causes the grid frequency to move away from its nominal value, and this can be regulated using ESS to improve quality of electricity.
        Deploying ESS can also maximize utilization of coal-fired power plants to reduce power cost.

        Commercial/Industrial/Housing

        PA1602_ESS_09.jpgPA1602_ESS_10.jpg

        · Load Leveling
        Time of use electricity pricing has three different pricing for light load, heavy load and maximum load. Electricity is charged during hours of light load and discharged during maximum load to reduce energy charge on your bill.
        · Back-up Power
        In case of blackout, ESS supplies electricity enabling swift response to emergencies.
        · Peak Shaving
        When electricity usage goes beyond what is contracted, electricity will be provided by ESS to prevent demand charge on your bill from going up.

        Microgrid

        PA1602_ESS_11.jpg

        · Grid connection/stand-alone
        A microgrid is a discrete energy system consisting of diesel power generation, renewable energy, ESS, etc. and loads capable of operating in parallel with, or independently from, the main power grid.
        ESS helps stabilize the grid system through power smoothing control as well as voltage and frequency regulation.

        BSS

        PA1602_ESS_12.jpg

        · Battery Swapping Station (BSS)
        BSS is an optimal charging station for automatic battery swapping electric buses. When battery is running out of energy, a robot removes the battery pack from the bus and places on the top of the charging station for charging.
        Bus stops are equipped with charging stations and battery is changed while the bus is stopped at bus stops.

        下載

        主題 分類 語言 修改日期

        客戶支持

        常見問題 more
        聯系我們 more
        top